-40%
LUDLUM 2200 Scaler ratemeter + 182 Radon Flask Detector, 264 Printing Calculator
$ 685.87
- Description
- Size Guide
Description
LUDLUM 2200 Scaler ratemeter with 182 Radon Flask Detector and 264 printing calculatorIncludes CE Certification sheet
This sale is for a LUDLUM Model 2200 Scaler ratemeter and Model 182 Radon Flask Detector with 264 printing calculator - includes CE certification paper
Condition:
We just received this from lab surplus. Used, fully functional with warranty.
Warranty:
30 Day Warranty.
We pledge to offer the best service and warranty to all of our customers! We are extending a 30 Day warranty on this item.
This is our way of saying thank you for allowing us to serve you.
Certification:
This is an genuine product from this manufacturer.
Web Information:
Features
General Purpose Scaler/Ratemeter
Single Channel Analyzer
Supports Wide Range of External Detectors
95-250 VAC Power Input
Portable Battery Operation
RS-232 Interface to Printer or PC
Introduction
The Model 2200 is a general purpose scaler with an accompanying ratemeter, and is typically used for counting samples. Its rugged design and construction allow both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2200 supports GM, proportional, and scintillator-type detectors, and provides fine adjustment controls for setting the high-voltage and threshold settings.
An adjustable discriminator and an adjustable window allow the user to count pulses within a user specified energy range. This portable unit can be powered by wall current or by four "D" cell batteries. The latter allows for continued operations during power interruptions. An optional printer (Model 4167-386) is available for hard copy archival of wipe test results.
The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the
Model 243
well scintillator (NaTl) detector. The Well Counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher energy isotopes like
131
I.
Specifications
INDICATED USE: single channel analyzing, gross counting
SUGGESTED DETECTORS: GM, proportional, scintillation
CONNECTOR: series “C” (others available)
SCALER: six-digit LED display providing a range of 0–999999 counts
SCALER LINEARITY: reading within 2% of true value
TIMER: push-wheel adjustment from 0–999 minutes with selectable X0.1 and X1 multipliers
RATEMETER: 0–500,000 cpm total range
METER DIAL: 0–500 cpm, 0-2.5 kV, BAT TEST
MULTIPLIERS: x1, x10, x100, x1000
RATEMETER LINEARITY: reading within 10% of true value
RESPONSE: toggle switch for FAST (4 seconds) or SLOW (22 seconds), from 10% to 90% of final reading
ZERO: pushbutton to zero meter
HIGH VOLTAGE: adjustable from 200–2500 volts (will support 60-megohm scintillation loads)
THRESHOLD: adjustable from 1.00–10.00
WINDOW: adjustable from 0 to 10.0 above the threshold setting (can be enabled or disabled)
DISCRIMINATOR: adjustable from 2–100 mV at threshold setting of 1.00
RS-232: 9-pin connector allowing for printer or computer interface
METER: 6.4 cm (2.5 in.) arc, 1 mA movement analog type
POWER: 95–250 Vac, 50–60 Hz or 4 “D” cell batteries
BATTERY LIFE: typically 120 hours with alkaline batteries (battery condition can be checked on meter)
TEMPERATURE RANGE: -20 to 50 °C (-4 to 122 °F), may be certified to operate from -40 to 65 °C (-40 to 150 °F)
SIZE: 21.6 x 12.7 x 21.6 cm (8.5 x 5 x 8.5 in.) (H x W x L), excluding handle
WEIGHT: 3.4 kg (7.5 lb), including battery
Model 180 Radon Flask Detector:
Introduction
The Model 182 Radon Flask Counter is a light-tight sample box that uses scintillation techniques for the detection of radiation material. It consists of a light-tight cylindrical well, a two-inch photomultiplier tube (PMT) optically coupled to a light pipe, and an automatic high voltage On-Off switch.
During sample counting the radon flask is placed on the acrylic light pipe. The upper tube body assembly is held in place with two thumbscrews. A push-rod assembly will then automatically activate a microswitch allowing high voltage (HV) to be applied to the PMT. The HV is automatically disconnected upon removal of the tube. The cover may be removed without turning off the high voltage on the accompanying scaler/count-rate meter type instrument.
The Series "C" connector uses a one-wire system combining the HV and signal. A capacitor located in the tube socket blocks the signal part of the PMT. A terminal strip containing a filter circuit prevents unwanted noise from the microswitch's actuations.
Specifications
INDICATED USE: detection of radiation materials
PHOTOMULTIPLIER TUBE (PMT): 5/1 cm (2 in.) diameter, 14-pin 10-stage dynode string
OPERATING RANGE: 400 to 1250 V
MAXIMUM PMT VOLTAGE: 1500 V
CONNECTOR: standard Series "C"
DARK ADAPTION: function of scintillation material (ranges from 20 minutes to 48 hours)
MAXIMUM SAMPLE SIZE: 6.1 X 12.7 cm (2.4 x 5 in.) (Dia x H)
FINISH: black powder coat (inside and outside)
TEMPERATURE RANGE: -20 TO 50 °C (-4 TO 122 °F); may be certified for operation from -40 to 65 °C (-40 to 150 °F)
ENVIRONMENTAL: maximum humidity of less than 95% (non-condensing)
DYNODE STRING RESISTANCE: 60 Megohm
SIZE: 8.9 x 38.1 cm (3.5 x 15 in.) (Dia x H) with a 15.2 x 15.2 cm (6 x 6 in.) square base
WEIGHT: 4.5 kg (10 lb)